Showing posts with label Meloxicam Injection Assay (MOA) By HPLC. Show all posts
Showing posts with label Meloxicam Injection Assay (MOA) By HPLC. Show all posts

Monday, 12 July 2021

Meloxicam Injection Assay (By HPLC) Finished Product | Test Procedure | Method of analysis (MOA) |

 


Meloxicam Injection Assay (MOA) By HPLC


Sample Preparation

Weigh sample equivalent 40 mg of Meloxicam in 100 ml of volumetric flask, add 0.3 ml of 0.4 M sodium hydroxide and shake well and dilute to 100 ml with Methanol ( 400 mcg )

 

Standard Preparation

Take 40 mg of Meloxicam WS in  100 ml volumetric flask and dilute with methanol  upto 100 ml ( 400 mcg )

 

 

Chromatographic Conditions

Column                      - C18 (10 cm × 4.0 mm) 10 µm or equivalent

Flow Rate                       - 1.0 ml/minute. 

Column temperature    - Ambient

Detection wavelengths - 350 nm. 

Inject                                 - 10 µL of each solution. 

----------------------------------------------------------------------------------

Time          Mobile Phase A    Mobile Phase B    Comment

( Minutes)   (% v/v )                       (% v/v )           

----------------------------------------------------------------------------------

 0 – 2.5                     60                                       40                       Isocratic

2.5 - 12               60 → 30                              40 → 70                  Linear Gradient

12 - 25                     30                                        70                       Isocratic

25 - 26                30 → 60                             70 → 40                  Linear Gradient

26 - 30                     60                                        40                       Re- equilibration

-----------------------------------------------------------------------------------

 

Calculation